How To Calculate Toroidal Transformers
A toroidal transformer is a transformer shaped like a doughnut. It has a round iron core with a coil of insulated wire wrapped around it. The iron core with the coil of wire is also called the "winding." Once powered, the winding generates a magnetic field and stores energy. The amount of energy is measured in units of inductance. As with most transformers, toroidal transformers have both a primary and secondary inductive winding, which is used to step down or step up the input voltage applied to the primary winding.
Step 1
Determine the number of turns in the primary winding of the transformer. Call this value "N." Refer to the transformer specifications. As an example, assume N is 300 turns.
Step 2
Find the radius of the transformer. Refer to transformer specifications. As an example, assume radius is 0.030 meters.
Step 3
Calculate the area using the formula A = π * r² where π is 3.1415. Continuing with the example:
A = 3.1415 * (0.030)(0.030) = 0.0028 square meters
Step 4
Calculate the inductance of the primary winding using the formula L = (μ0 N² A) / 2 π r, where μ0 is the relative permeability of space with a value of 4 π 10^-7 T m/A. Continuing with the example:
μ0 = 4 π 10^-7 = 4 3.1415 10^-7 = 12.56 * 10^-7.
L = [(12.56 * 10^-7)(300^2)(0.0028)] / [(2)(3.1415)(0.030)] = 0.000316 / 0.188 = 0.00168 henries or 1.68 millihenries.